Á¦¸ñ ¾øÀ½

 
 
 
 
 
 
 
 
HOME > ½Ã½ºÅÛ > SUN > STORAGE > Sun StorEdge 9980
 
 
Data Center ½ºÅ丮Áö
Sun StorEdge 9970 Sun StorEdge 9980
Midrange ½ºÅ丮Áö
Sun StorEdge 3900 Series Sun StorEdge 6000 Family
Sun StorEdge T3 Array- Enterprise Sun StorEdge A5200 Array
Workgroup ½ºÅ丮Áö
Sun StorEdge A1000/D1000 Sun StorEdge 3000 Family
Sun StorEdge S1 Array Sun StorEdge D2 Array Netra st A1000/D1000

¡Ø Sun StorEdge 9980 ½Ã½ºÅÛÀº ÃÖ°í ¼öÁØÀÇ ¼º´É, °¡¿ë¼º
¹× ¿ë·®À» ¿ä±¸Çϴ ȯ°æÀ» À§ÇØ ¼³°èµÆ½À´Ï´Ù. ÀÌ´Â ½ºÅä
¸®Áö °¡»óÈ­¿Í ÇÔ²² ÃÖ´ë 74.7TB±îÁöÀÇ È®À强À» Á¦°øÇϸç
´ë±Ô¸ð ÅëÇÕ°ú µ¥ÀÌÅÍ Áý¾àÀûÀÎ ¾ÖÇø®ÄÉÀ̼ǿ¡
ÀÌ»óÀûÀÔ´Ï´Ù.

¢Ê ÁÖ¿ä ¾ÖÇø®ÄÉÀÌ¼Ç ----------------------------------------------------------------------------
¢Ñ ¶Ù¾î³­ ¼º´É, È®À强, °¡¿ë¼º ¹× Ä¿³ØÆ¼ºñƼ¸¦ ÇÊ¿ä·Î ÇÏ´Â µ¥ÀÌÅÍ ¼¾ÅÍ ½ºÅ丮Áö ÅëÇÕ, Á÷Á¢ ¿¬°á ¸ÞÀÎÇÁ·¹ÀÓ Ä¿³ØÆ¼ºñƼ ¹× SAN ¿¬°á ¾ÖÇø®ÄÉÀ̼ÇÀ» À§ÇÑ ÃÖ»óÀÇ Ç÷§ÆûÀ» Á¦°øÇÕ´Ï´Ù.

¢Ê ÁÖ¿ä »ç¾ç -------------------------------------------------------------------------
¢Ñ ÃÖ´ë 74.7 TB ±âº» ¿ë·®(64.3 TB RAID 5 »ç¿ëÀÚ ¿ë·®)
¢Ñ ÃÖ´ë 64 GB ij½Ã
¢Ñ 15 GB/s ÃÖ´ë ³»ºÎ ´ë¿ªÆø(Àüü)
¢Ñ ·Î¿ì ÇÁ·ÎÆÄÀÏ ÆÄÀ̹ö ä³Î µð½ºÅ© µå¶óÀ̺긦 »ç¿ëÇÏ´Â 1024 µå¶óÀÌºê ¿ë·®(ÃÖ´ë 4°³ÀÇ ÇÖ ½ºÆä¾î)
¢Ñ SAN Ä¿³ØÆ¼ºñƼ - 4000°³ ÀÌ»óÀÇ È£½ºÆ® ¿¬°á ó¸®
¢Ñ 32°³ÀÇ ÀÎÅÍÆäÀ̽º(ÆÄÀ̹ö ä³Î, ESCON ¹× FICON) ¼ö¿ë
¢Ñ RAID 5 ¶Ç´Â RAID 1+¸¦ Áö¿øÇÔÀ¸·Î½á °í°´ÀÌ ÀÚü ȯ°æ¿¡ °¡Àå ÀÌ»óÀûÀÎ µð½ºÅ© µå¶óÀÌºê º¸È£, º¹±¸ ±â´É ¹× ¼º´ÉÀ» ¼±ÅÃÇÒ ¼ö ÀÖµµ·Ï º¸Àå

¢Ê ÁÖ¿ä ÀåÁ¡ -------------------------------------------------------------------------
¢Ñ °¡¿ë¼º ¹× È®À强ÀÌ ¶Ù¾î³­ ÀÌ °í¼º´É ½ºÅ丮Áö ½Ã½ºÅÛÀº ´Ù¾çÇÑ ÀÎÅÍÆäÀ̽º¿¡ ´ëÇÑ À¯¿¬¼ºÀ» Á¦°øÇÏ´Â 2¼¼´ë ½ºÀ§Ä¡µå ÆÐºê¸¯ ¾ÆÅ°ÅØÃ³, °¡»óÈ­ ±â´É ¹× ¶Ù¾î³­ ±â´ÉÀÇ ¾ÆÅ°ÅØÃ³¸¦ Æ÷ÇÔÇϰí ÀÖ½À´Ï´Ù. °£ÆíÇÑ ÀÚµ¿È­ ¼ÒÇÁÆ®¿þ¾î ÅøÀ» ÅëÇØ ½ºÅ丮Áö °ü¸®¸¦ Áß¾Ó ÁýÁßÇÔÀ¸·Î½á ÇÊ¿äÇÑ ½Ã°£°ú ÀÚ¿øÀ» ÁÙÀÏ ¼ö ÀÖ°Ô µË´Ï´Ù. º» ½Ã½ºÅÛ¿¡´Â Çϵå¿þ¾î ¹× Æß¿þ¾î Áߺ¹, Ȩ ÄÝ ±â´ÉÀ» °®Ãá »çÀü ´ëóÀû À¯Áö º¸¼ö ¼­ºñ½º°¡ Æ÷ÇԵǾî ÀÖÀ¸¸ç ¹Ì¼Ç Å©¸®Æ¼ÄÃÇÑ Áö¿ø ¼¾Å͸¦ ÅëÇØ Á¦°øµÇ´Â Àü¼¼°è Áö¿øÀÌ Áï°¢ Á¦°øµË´Ï´Ù. »Ó¸¸ ¾Æ´Ï¶ó, º» ½Ã½ºÅÛÀº ½ãÀÇ Áö¼ÓÀûÀÎ ÀÎÁõ ¹× ¼º´É ÇÁ·Î±×·¥¿¡ Æ÷ÇÔµÇ¸ç °í°´ÀÇ µ¥ÀÌÅÍ ¼¾ÅÍ È¯°æ¿¡ ¼Õ½±°Ô ÅëÇÕµÉ ¼ö ÀÖ½À´Ï´Ù.

¢Ê ÁÖ¿ä °ü·Ã ¼ÒÇÁÆ®¿þ¾î ---------------------------------------------------------------
¢Ñ Sun StorEdge[tm] Resource Management Suite ¼ÒÇÁÆ®¿þ¾î
¢Ñ Sun StorEdge[tm] Availability Suite ¼ÒÇÁÆ®¿þ¾î
¢Ñ Sun StorEdge[tm] Performance Suite ¼ÒÇÁÆ®¿þ¾î
¢Ñ Sun StorEdge[tm] Utilization Suite ¼ÒÇÁÆ®¿þ¾î
¢Ñ Sun StorEdge[tm] 9900 ½Ã¸®Áî ¼ÒÇÁÆ®¿þ¾î

¢Ê ¿ä±¸»çÇ× -------------------------------------------------------------------------
¢Ñ Solaris[tm] ¿î¿µ ȯ°æ ¹× Sun[tm] Cluster 3.0 ±¸¼º¿¡ ÃÖÀûÈ­

¢Ê ¼­ºñ½º ¹× Áö¿ø -------------------------------------------------------------------------------
¢Ñ ½ã ±³À° ¼­ºñ½º
¢Ñ ½ã Àü¹®°¡ ¼­ºñ½º
¢Ñ ½ã Áö¿ø ¼­ºñ½º

¢Ê °³¿ä -----------------------------------------------------------------------------
¢Ñ Sun StorEdge[tm] 9980 ½Ã½ºÅÛÀº ´ë±Ô¸ð µ¥ÀÌÅÍ ¼¾ÅÍ È¯°æ¿¡ ÇÊ¿äÇÑ ³ôÀº ¼öÁØÀÇ ¼º´É°ú ¿ë·®À» Á¦°øÇÕ´Ï´Ù. °¡¿ë¼º ¹× È®À强ÀÌ ¶Ù¾î³­ ÀÌ ½ºÅ丮Áö ½Ã½ºÅÛÀº ÄÁÆ®·Ñ ÇÁ·¹ÀÓ°ú ¾î·¹ÀÌ ÇÁ·¹ÀÓ µî 2 °¡Áö ÇÁ·¹ÀÓÀ¸·Î ÀÌ·ç¾îÁø ±âº» ±¸¼ºÀ» °®Ãß°í ÀÖ½À´Ï´Ù. ÄÁÆ®·Ñ ÇÁ·¹ÀÓ¿¡´Â ij½Ã¿Í ½ºÀ§Ä¡ ¸ðµâ, È£½ºÆ®¿Í µå¶óÀ̺ê ÀÎÅÍÆäÀ̽º, µð½ºÅ© ¾î·¹ÀÌ ÇÁ·Î¼¼¼­ ¹× ¼­ºñ½º ÇÁ·Î¼¼¼­°¡ Æ÷ÇԵǾî ÀÖ½À´Ï´Ù. Áߺ¹ Àü¿ø °ø±Þ ÀåÄ¡¿Í ÃÖ´ë 256°³ÀÇ µå¶óÀ̺긦 °®Ãá ¾î·¹ÀÌ ÇÁ·¹ÀÓÀ» ÃÖ´ë 4°³±îÁö Áö¿øÇÒ ¼ö ÀÖ½À´Ï´Ù. ƯÈ÷ ÀÌ ½Ã½ºÅÛÀÇ °¡»óÈ­ ±â´ÉÀº ¿©·¯ È£½ºÆ®·Î ¿¬°áÇÒ ¼ö ÀÖµµ·Ï Áö¿øÇÔÀ¸·Î½á ½ºÅ丮ÁöÀÇ ÅëÇÕÀ» ÅëÇØ ÃÑ ¼ÒÀ¯ ºñ¿ë(TCO)À» ÁÙÀÏ ¼ö ÀÖµµ·Ï Çϸç SAN ÀÎÇÁ¶ó¸¦ º¸´Ù À¯¿¬ÇÏ°Ô ±¸¼ºÇÒ ¼ö ÀÖµµ·Ï ÇÕ´Ï´Ù. º» ½ºÅ丮Áö ½Ã½ºÅÛÀº ¿î¿µ ¹× Á¦¾î°¡ ½±°í º¸´Ù °£ÆíÇÏ°Ô µ¥ÀÌÅ͸¦ °ü¸®ÇÒ ¼ö ÀÖ½À´Ï´Ù. ¼ÒÇÁÆ®¿þ¾î´Â °æ·Î °ü¸®, ½Ç½Ã°£ º¹Á¦, ÀçÇØ º¹±¸¸¦ À§ÇÑ ¿ø°Ý ¹Ì·¯¸µÀ» Æ÷ÇÔÇØ µ¥ÀÌÅÍ ¼¾ÅÍ È¯°æ¿¡¼­ ÀϹÝÀûÀ¸·Î »ç¿ëµÇ´Â ÁÖ¿ä ½ºÅ丮Áö ¾ÖÇø®ÄÉÀ̼ÇÀ» Áö¿øÇϴµ¥ »ç¿ëÇÒ ¼ö ÀÖ½À´Ï´Ù.


Data Center ½ºÅ丮Áö
Sun StorEdge 9970 Sun StorEdge 9980
Midrange ½ºÅ丮Áö
Sun StorEdge 3900 Series Sun StorEdge 6000 Family
Sun StorEdge T3 Array- Enterprise Sun StorEdge A5200 Array
Workgroup ½ºÅ丮Áö
Sun StorEdge A1000/D1000 Sun StorEdge 3000 Family
Sun StorEdge S1 Array Sun StorEdge D2 Array Netra st A1000/D1000